Interconnect configuration has been detected but there is no logical interconnect associated with the interconnect

Symptom

Interconnect configuration has been detected but there is no logical interconnect associated with the interconnect. Unreferenced logical JBODs have been discovered. These are logical JBODs that are configured in the hardware, but for which there is no reference from any server profile. These logical JBODs will be removed and data will be lost when a logical enclosure with SAS logical interconnect is created.

ID: dfrm.ConfigMismatch.From.Physical.To.Logical

Severity: Critical

Health Category: SAS interconnect

Resource URI: /rest/sas-interconnects/

Action
  • To preserve the data, restore a backup that contains the server profiles and logical JBODs.
  • If a backup is not available, do the following:
    1. Back up logical drive and logical JBOD data on the specified server hardware.
    2. Create a logical enclosure with SAS logical interconnect, which will remove unreferenced JBODs and clear this alert.
    3. Create server profiles for the specified server hardware, and add logical JBODs to replace those removed in the previous step.