There is not enough power available from the power subsystem
There is not enough power available from the power subsystem to meet the current power redundancy mode settings. The enclosure and/or components may lose power if subsequent power failures occur.
ID: hpris.emRegistry.<version>.PowerSubsystemRedundancyLost
Severity: Warning
Resource URI: /rest/v1/Chassis/1/PowerMetrics/
The number of operational power supplies is not sufficient to support the frame with the current power redundancy mode settings.
- Verify that power supplies are properly installed and are connected to input power.
- If possible, install additional power supplies.
- If the issue persists, consider changing the input power mode for the logical enclosure to "Redundant power supply."