Unable to validate the signature for the X component contained with the firmware baseline Y

Symptom

Unable to validate the signature for the X component contained with the firmware baseline Y. The component is either not signed or has an invalid signature.

This alert is new in HPE OneView 3.1.

ID: firmware-drivers.fwbundleValidity.firmwareBundle.accessDenied

Severity: Critical

Health Category: Firmware

Resource URI: /rest/firmware-drivers/{baseline name}

Action
  1. Be sure that the OA/EM, VC, and iLO components have been created with valid signatures. To ensure this, make sure that these components have been downloaded from a valid firmware baseline, or are hotfixes provided by Hewlett Packard Enterprise.
  2. Retry to validate the signature with a firmware baseline having a valid component.