1738-Slot # Drive Array – Storage Enclosure Redundant Cabling Problem Detected
1738-Slot # Drive Array – Storage Enclosure Redundant Cabling Problem Detected. Check storage box I/O module and cable to restore redundant paths to the following disk drive(s):
Port # Box # Bay(s) #
Select “F1” to persist with this message on reboots until failed paths are restored
Select “F2” to disable this message on reboots – no further POST message for recurring path failure with logical drive(s) corresponding to these disk drives
An issue exists with the storage enclosure redundant cabling. A single path was found to drives that were previously connected redundantly.
-
Check the storage box I/O module and cable to restore redundant paths to the drives, and then do one of the following:
- If the redundant cables/paths were not purposefully removed, press the F1 key to display this message on reboot until the issue is resolved. The drives should be accessible through the remaining path.
- If the redundant paths were purposefully removed, press the F2 key to disable this message on all subsequent reboots.