The downlink port(s) to the server hardware in bay(s) X from interconnect Y are disabled
The downlink port(s) to the server hardware in bay(s) X from interconnect Y are disabled due to a mismatch with mezzanine card(s) Z in the server hardware.
ID: hpris.emRegistry.<version>.InterconnectConfigurationFault
Severity: Critical
Resource URI: /rest/v1/Chassis/1/InterconnectBays/1/
Interconnect Y is not compatible with mezzanine card Z.
-
If the error occurs on a single compute module, do the following:
- Remove the component in bay X.
- Move mezzanine card Y to a slot that matches the interconnect type.
- Reinstall the component in bay X.
- If the error occurs on multiple compute modules, consider moving interconnect Z to a bay that matches the mezzanine card type. For more information, see the frame setup and installation guide on the Hewlett Packard Enterprise website.