The persistent memory drive is read only
A persistent memory drive marked as "read only" usually indicates that the underlying NVDIMM detected is not armed for backup during the boot process.
Solution 1Cause
Action
Previous backup operation failed.
The current restore operation failed.
A general arming error occurred.
An erase error occurred.
An NVDIMM controller error occurred.
Check the IML for the cause of the failure or error. Perform the action recommended in the IML.
Solution 2Cause
Action
The persistent memory backup power requirements exceed the available backup battery power.
Remove any hardware that was recently added to the
compute module.
Solution 3Cause
Action
The backup energy source is not sufficiently charged and the charging process was skipped by the user.
Reboot the system and wait for the backup energy source to sufficiently charge.
Solution 4Cause
Action
The backup energy source is not sufficiently charged and the charging process timed out.