Drives are failed

Action:

  1. Be sure no loose connections exist. For more information, see "Resolving loose connections."
  2. Check to see if an update is available for any of the following:
  3. Be sure the drive or backplane is cabled properly.
  4. Be sure the drive data cable is working by replacing it with a known functional cable.
  5. Be sure drive blanks are installed properly when the server is operating. Drives may overheat and cause sluggish response or drive failure.
  6. Run HPE Insight Diagnostics. Then, replace failed components as indicated.
  7. Run HPE SSA and check the status of the failed drive. For more information, see "HPE Smart Storage Administrator."
  8. Be sure the replacement drives within an array are the same size or larger.
  9. Be sure the replacement drives within an array are the same drive type, such as SAS, SATA, or SSD.
  10. Power cycle the server. If the drive shows up, check to see if the drive firmware needs to be updated.