When the health LED on the front panel illuminates either amber or red, the server is experiencing a health event. Combinations of illuminated Systems Insight Display LEDs, the system power LED, and the health LED indicate system status.
Systems Insight Display LED and color |
Health LED |
System power LED |
Status |
---|---|---|---|
Processor (amber) |
Red |
Amber |
One or more of the following conditions may exist:
|
Processor (amber) |
Amber |
Green |
Processor in socket X is in a pre-failure condition. |
DIMM (amber) |
Red |
Green |
One or more DIMMs have failed. |
DIMM (amber) |
Amber |
Green |
DIMM in slot X is in a pre-failure condition. |
Over temp (amber) |
Amber |
Green |
The Health Driver has detected a cautionary temperature level. |
Over temp (amber) |
Red |
Amber |
The server has detected a hardware critical temperature level. |
PCI riser (amber) |
Red |
Green |
The PCI riser cage is not seated properly. |
Fan (amber) |
Amber |
Green |
One fan has failed or has been removed. |
Fan (amber) |
Red |
Green |
Two or more fans have failed or been removed. |
Power supply (amber) |
Red |
Amber |
One or more of the following conditions may exist:
|
Power supply (amber) |
Amber |
Green |
One or more of the following conditions may exist:
|
Power cap (off) |
— |
Amber |
Standby |
Power cap (green) |
— |
Flashing green |
Waiting for power |
Power cap (green) |
— |
Green |
Power is available. |
Power cap (flashing amber) |
— |
Amber |
Power is not available. |
|
IMPORTANT: If more than one DIMM slot LED is illuminated, further troubleshooting is required. Test each bank of DIMMs by removing all other DIMMs. Isolate the failed DIMM by replacing each DIMM in a bank with a known working DIMM. |