Secondary PCI riser cage option

To install the component:

  1. Power down the server.
  2. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  3. Extend the server from the rack.
  4. Remove the access panel.

    CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all PCI slots have either an expansion slot cover or an expansion board installed.

  5. Remove the secondary PCI riser blank.

    Removing the secondary PCI riser blank

  6. Remove the blank from the optional 3-slot PCI riser cage.

    Removing a blank from the secondary PCI riser cage

  7. Install an expansion board into the PCI riser cage.

    Installing an option card into the secondary PCI riser cage

  8. Install the optional 3-slot PCI riser cage.

    Installing the secondary PCI riser cage

  9. Install the access panel.
  10. Slide the server into the rack.
  11. Connect each power cord to the server.
  12. Connect each power cord to the power source.