Previous Topic

Next Topic

Stand-up SAS controller cable option

The SAS controller cable option is required to enable a PCIe slot-based controller to drive the internal top bay drives. Otherwise, the drive indicator signaling will not correctly match the accessed drive. The bottom bay SAS drives cannot be controlled by a PCIe slot-based controller.

CAUTION: To prevent damage to electrical components, take the appropriate anti-static precautions before beginning any system installation. Improper grounding can cause electrostatic discharge.

To install the component:

  1. Power down the server.
  2. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  3. Remove the access panel.
  4. Install the backplane, and then tighten the thumbscrews.

    Installing the drive backplane

    Be sure the corners of the backplane are aligned under the tabs.

    Drive backplane, installed

  5. Connect the optional SAS controller cable.

    Connecting the optional SAS controller cable

  6. Connect the power cable.

    Connecting the drive backplane power cable

  7. Install the access panel.
  8. Remove all bezel blanks.

    Removing the drive blank

  9. Install the drives (Drive option, Drive option).

    Installing a drive

  10. Install blanks in unused drive bays.

    Installing a SFF drive blank

  11. Connect each power cord to the server.
  12. Connect each power cord to the power source.
  13. Power up the server.