System health and power redundancy
Good power supplies are detected at boot time and system power redundancy is set at boot time.
Selected power supply mode |
3+1 Power configuration |
2+2 Power configuration |
4 PSUs detected at POST |
Health = Green (Normal) Redundant configuration |
Health = Green (Normal) Redundant configuration |
3 PSUs detected at POST |
Health = Green (Normal) Non-Redundant configuration |
Health = Green (Normal) Redundant configuration |
2 PSUs detected at POST |
Health = Red (critical) System cannot power on |
Health = Green (Normal) Redundant configuration |
1 PSUs detected at POST |
Health = Red (critical) System cannot power on |
Health = Red (critical) System cannot power on |
System health and behavior if power supplies fail during server operation
-
3+1 power supply mode
-
2+2 power supply mode
Detected PSUs at POST
4 PSUs detected at POST
3 PSUs detected at POST
2 PSUs detected at POST
no PSU failure
Health = Green (Normal)
Health = Green (Normal)
Health = Green (Normal)
1 PSU failure
Health = Amber
Degraded operation
Health = Amber
Degraded operation
Health = Red
System gracefully shuts down
2 PSU failure
Health = Amber
Degraded operation
Health = Red
System gracefully shuts down
—
3 PSU failure
Health = Red
System gracefully shuts down
—
—