Selecting the power supply mode
When the x4 Redundant Power Supply Enablement Kit is installed, system power supply capacity increases from 2 to 4 PSUs, and the system can be configured for 1 or 2 different power sources. In the default 3+1 mode one PSU is redundant. Select 2+2 power supply mode to support power supplied from two different power sources
System ROM must be upgraded to P92 v2.30 for power supply mode selection to be available.
-
Reboot the server.
The server restarts and the POST screen appears.
-
Press F9.
The system utilities screen appears.
-
Select System Configuration —> BIOS/Platform Configuration (RBSU) —> Advanced Options —> Redundant Power Supply Mode, and then press Enter.
-
Select Configured for 3+1 Redundancy or Configured for 2+2 Redundancy and then press Enter.
-
Press F10 to save the selection.
-
Press Y to save the changes.
-
Select Exit and resume system boot, and press Enter. The server continues the normal boot process.