Previous Topic

Next Topic

Dual FlexibleLOM riser options

To install the component:

  1. Power down the server associated with the I/O module.
  2. Remove the server associated with the I/O module.
  3. If an I/O module blank is not installed in the associated even-numbered I/O module bay, install an I/O module blank in the associated even-numbered bay.

    Installing the I/O module blank

  4. Remove the I/O module.

    Removing the I/O module

  5. Remove the support arm from the I/O module.

    Removing the support arm from the I/O module

  6. Using a T-10 Torx screwdriver, install the I/O module FlexibleLOM adapter and the support arm.

    Installing an I/O module FlexibleLOM adapter

  7. Install the I/O module.

    Installing an I/O module

  8. Install the server into the chassis.
  9. Connect all peripheral cables to the server.
  10. Press the Power On/Standby button.

    The server exits standby mode and applies full power to the system. The system power LED changes from amber to green.