General specifications

Weight and physical dimensions

Supported SFPs

Supported HBAs

Environmental requirements

To ensure proper operation, the switch must not be subjected to environmental conditions beyond those for which it was tested. The ranges specified in Environmental requirements list the acceptable environment for both operating and nonoperating conditions.

Environmental requirements
ConditionAcceptable range during operationAcceptable range during non-operation
Ambient temperature

Inlet air temperature up to 43°C (109.4°F) at sea level with an altitude derating of 1.0°C per every 1000 ft of elevation above sea level to a maximum operating altitude. For example, the maximum inlet air temperature requirement at 5000 ft above sea level is 38ºC.

Non-operating -40°C to 70°C (-40° to 158°F). Maximum rate of change is 20°C/Hr (36°F/Hr).

Humidity5 to 95% relative humidity, 38.7°C maximum wet bulb temperature, and non-condensing5% to 95% relative humidity, 38.7°C maximum wet bulb temperature, and non-condensing
Altitude0 to 10,000 ft (3 km) above sea level0 to 30,000 ft (9144 m) above sea level
Shock40 G, 2ms durationhalf-sine-wave shock—140 G, 2ms

square-wave shock—up to 80 G, 180 inches/s

Vibration0.002 G2/Hz, 10–500 Hz0.008 G2/Hz, 10–500 Hz