Insight Control server provisioning provides Build Plans and configuration files to use as a starting point when deploying HP Smart Array with a customized RAID configuration. Use these to derive a Build Plan and configuration file for the RAID configuration desired in your environment.
The HP-provided content (Build Plans and configuration files) cannot be edited and should be used as a reference. You must copy or use the content as a pattern, then edit the content to customize the RAID configuration for your environment.
These instructions are intended to help you customize and use the following HP-provided Build Plans and configuration files for your environment.
HP-provided Build Plans
-
ProLiant HW - Smart Array Capture Settings
-
ProLiant HW - Smart Array Erase
-
ProLiant HW - Smart Array Set RAID 1
HP-provided configuration files
-
Smart Array Configuration – Set RAID 1
-
Smart Array Configuration – Set RAID 5
-
Smart Array Configuration – Delete RAID Logical Volumes
It is assumed you are familiar with the HP Array Configuration Utility (ACU). The Build Plan ProLiant HW - Smart Array Set RAID 1
uses the HP ACU scripting toolkit with the configuration file Smart Array Configuration – Set RAID 1
as input.
To create a Build Plan to customize a RAID configuration
-
Create a configuration file in one of the following ways. The syntax of the configuration file must conform to the HP Array Configuration Utility (ACU) scripting tool.
-
Customize an HP-provided configuration file (“HP-provided configuration files”) by making a copy and then editing it. See Copy configuration files for additional information.
-
Use the Build Plan
ProLiant HW – Smart Array Capture Settings
to capture a configuration file from a Smart Array that is already configured and then customize it. -
Create a new configuration file from scratch as described in Create configuration files.
-
-
Make a copy of the Build Plan
ProLiant HW - Smart Array Set RAID 1
with Actions→Save as. -
Edit your copy of the Build Plan
ProLiant HW - Smart Array Set RAID 1
and replace the stepSmart Array Configuration - Set RAID 1
with the configuration file created in step 1.
IMPORTANT: Preserve the
Install path
parameter value when editing the deploy configuration file step of the Build Plan. The originalInstall path
is/tmp/sstk/hpacucli/acuinput.ini
and should match the parameter forManage Smart Array Configuration
.
NOTE: The
Manage Smart Array Configuration
script accepts the HP ACU scripting options[-internal | —external]
and[-reset]