Secondary PCI riser cage option

WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power cord to remove power from the server. The front panel Power On/Standby button does not completely shut off system power. Portions of the power supply and some internal circuitry remain active until AC power is removed.

CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all PCI slots have either an expansion slot cover or an expansion board installed.

IMPORTANT: The secondary PCI riser cage option requires both processors.

To install the component:

  1. Power down the server.
  2. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  3. Extend the server from the rack.
  4. Remove the access panel.
  5. Remove the PCI riser blank.

    Removing the PCI riser blank

  6. Remove the blank from the optional secondary PCI riser cage.

    Removing a blank from the PCI riser cage

  7. Install an expansion board into the PCI riser cage.

    Installing an option card into the PCI riser cage

  8. Install the optional secondary PCI riser cage.

    Installing the secondary PCI riser cage

  9. If not already installed, install the secondary processor.
  10. Install the access panel.
  11. Install the server into the rack.
  12. Connect each power cord to the server.
  13. Connect each power cord to the power source.
  14. Power up the server.