SAS drive backplane option
CAUTION: To prevent damage to electrical components, take the appropriate anti-static precautions before beginning any system installation. Improper grounding can cause electrostatic discharge. |
To install the component:
- Power down the server.
- Remove all power:
- Disconnect each power cord from the power source.
- Disconnect each power cord from the server.
- Remove the access panel.
- Extend the processor memory drawer approximately 2.54 to 5.1 cm (1 to 2 inches).
- Remove the SPI board.
- Install the backplane, and then tighten the thumbscrews.
Be sure the corners of the backplane are aligned under the tabs.
- Connect the data cable.
- Connect the power cable.
- Install the SPI board.
- Install the processor memory drawer (Remove the processor memory drawer cover, Install the processor memory drawer).
- Install the access panel.
- Remove all bezel blanks.
- Install the drives (Drive option, Drive option).
- Install blanks in unused drive bays.
- Connect each power cord to the server.
- Connect each power cord to the power source.
- Power up the server.