Previous Topic

Next Topic

SAS drive backplane option

CAUTION: To prevent damage to electrical components, take the appropriate anti-static precautions before beginning any system installation. Improper grounding can cause electrostatic discharge.

To install the component:

  1. Power down the server.
  2. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  3. Remove the access panel.
  4. Extend the processor memory drawer approximately 2.54 to 5.1 cm (1 to 2 inches).

    Extending the processor memory drawer

  5. Remove the SPI board.

    Removing the SPI board

  6. Install the backplane, and then tighten the thumbscrews.

    Installing the drive backplane

    Be sure the corners of the backplane are aligned under the tabs.

    Drive backplane, installed

  7. Connect the data cable.

    Connecting the drive backplane data cable

  8. Connect the power cable.

    Connecting the drive backplane power cable

  9. Install the SPI board.
  10. Install the processor memory drawer (Remove the processor memory drawer cover, Install the processor memory drawer).
  11. Install the access panel.
  12. Remove all bezel blanks.

    Removing the drive blank

  13. Install the drives (Drive option, Drive option).

    Installing a drive

  14. Install blanks in unused drive bays.

    Install an SFF drive blank

  15. Connect each power cord to the server.
  16. Connect each power cord to the power source.
  17. Power up the server.