Previous Topic

Next Topic

M.2 SSD enablement option

For more information about product features, specifications, options, configurations, and compatibility, see the product QuickSpecs on the Hewlett Packard Enterprise website.

To install the component:

  1. Power down the server.
  2. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  3. Do one of the following:
  4. Remove the access panel.
  5. Remove the PCI riser cage.
  6. Do one of the following:
    • If you are using the two-slot PCI riser cage, remove the bottom slot cover.

      Removing the riser slot cover

    • If you are using the three-slot PCI riser cage, remove the middle slot cover.

      Removing the riser slot 2 cover

  7. Install the M.2 SSD enablement board. Verify that the board is firmly seated in the slot.

    Installing the M.2 SSD enablement board in the PCI riser cage

  8. Connect the SATA cables to the M.2 SSD enablement board.

    Connecting the SATA cables to the M.2 SSD enablement board

  9. Install the PCI riser cage.
  10. Connect the M.2 SSD SATA cables to the system board.
    • M.2 SSD cabling from the primary PCIe riser location

      Connecting the M.2 SSD SATA cables from the primary PCIe riser location

    • M.2 SSD cabling from the secondary PCIe riser location

      Connecting the M.2 SSD SATA cables from the secondary PCIe riser location

      CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all expansion slots have either an expansion slot cover or an expansion board installed.

  11. Install the access panel.
  12. Do one of the following:
  13. Power up the server.