Installing an HPE Host Bus Adapter
NOTE: Smart Array controllers are not supported in PCIe slot 5.
To install the component:
Procedure
- Back up all server data.
-
Do one of the following:
- For tower models, open and remove the tower bezel.
- For rack models, if installed, remove the security bezel.
- Power down the server.
- Remove all power:
-
Do one of the following:
- For tower models, place the server on a flat, level surface with the access panel facing up.
- For rack models, extend the server from the rack.
- Remove the access panel.
- Remove the air baffle.
- Remove the fan cage.
-
Install the host bus adapter.
-
Select an available expansion slot from PCIe slots 1 to 4 or 6 to 9, and then remove the slot cover of the corresponding slot.
If installing the HBA in slots 6-9, a second processor option must be installed first. See "Processor option."
-
Install the host bus adapter, verify that the board is firmly seated in the slot.
- Close the slot retainer or the screw to secure the controller.
-
Select an available expansion slot from PCIe slots 1 to 4 or 6 to 9, and then remove the slot cover of the corresponding slot.
- Connect one end of each Mini-SAS cable to the host bus adapter and the other end of the cable to the drive backplane:
- Install the fan cage.
- Install the air baffle.
- Install the access panel.
- Do one of the following:
- Connect each power cord to the server .
- Connect each power cord to the power source.
- Power up the server.
-
Do one of the following:
- For tower models, install the tower bezel.
- For rack models, install the security bezel.