Removing and replacing the Pensando DSP iLO Sideband ALOM Module

IMPORTANT:

Before beginning this procedure, follow the warnings and cautions.

Prerequisites

Before you perform this procedure, make sure that you have the following items available:

  • The components included with the hardware option kit

  • T-15 Torx screwdriver

Procedure
  1. If installed, remove the bezel.
  2. Power down the server.
  3. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  4. Do one of the following:
  5. Remove the access panel.
  6. Disconnect the auxiliary cable from the DSC-25 card before removing the PCIe riser cage.
    NOTE:

    The PCIe riser cage is not shown in this illustration for clarity purposes.



  7. Remove the primary riser cage.
  8. Disconnect the auxiliary cable from the ALOM module using the thumb screw.
    NOTE:

    Be sure not to twist the cable.



  9. Remove the Pensando DSP iLO Sideband ALOM Module from the FlexibleLOM adapter connector on the system board.



To replace the component, reverse the removal procedure.