The LINK port on frame link module X is linked but a redundant frame link module is missing

Symptom

The LINK port on frame link module X is linked but a redundant frame link module is missing. A redundant frame link module is expected if the LINK port is linked.

ID: hpris.emRegistry.<version>.EmPeerEmNeeded

Severity: Warning

Health Category: Enclosure

Resource URI: ?/rest/v1/Switches/1/SwitchPorts/1/

Cause

The external link on the frame link module is connected but the internal link is down because a peer frame link module is not present.

Action
  • Do one of the following:
    • Install a redundant frame link module.
    • Disconnect the LINK port on frame link module X.

    For more information, see the frame setup and installation guide on the Hewlett Packard Enterprise website.