SymptomUnable to communicate with the drive in bay X. This drive is part of logical JBOD Y and is being used by server profile Z.
This alert is new starting with HPE OneView 4.2.
ID: hpris.HpSmartStorageDiskDrive.CommunicationFailure.attachedJbod
Severity: Critical
Health Category: drive-enclosure
Resource URI: /rest/drive-enclosures/
Action-
Remove and then reinstall the drive in the specified drive bay.
-
If the issue persists, replace the drive.
-
Verify the drive status and volume integrity by using the Smart Storage Administrator:
- If this drive is part of a non-fault-tolerant configuration, back up all data before replacing the drive, and then restore all data.
- If this drive is part of a fault-tolerant configuration, do not replace this drive unless all other drives in the volume are online.