Controller status is now X for controller located in Y
Alert Type ID: trap.cpqDa6CntlrStatusChange
Description: Controller status is now X for controller located in Y.
Severity: Critical
Health Category: Storage
Resource URI: /rest/server-hardware/{UUID}
Source MIB: CPQIDA-MIB
The agent has detected a change in the status of a drive array controller. The variable
cpqDaCntlrBoardStatus
indicates the current controller status.
NOTE:
Refer to the MIB file to see all of the variables for
cpqDACntrlBoardStatus
and the meaning of each variable.
-
If the controller status is
generalFailure
, reboot the server or replace the controller. -
Check the variable
cpqDaCntlrLastLockupCode
for the controller's last lockup code, and then do the following:- If the
cpqDaCntlrBoardStatus
variable iscableProblem
, check the cable connections between the controller and the storage system. - If the
cpqDaCntlrBoardStatus
variable iscacheModuleMissing
, the array controller is operating in an unsupported configuration and requires that a cache module be attached to the controller.
- If the