The adapter reported incomplete or invalid configuration data

Symptom

The adapter in X is present but reported incomplete or invalid configuration data.

This alert is new starting with HPE OneView 5.0.

ID: server-hardware.devices.adapter.discover.ADAPT_ERROR

Severity: Critical

Health Category: Operational

Resource URI: /rest/server-hardware/{UUID}

Action

Do the following, one at a time, until the issue is resolved:

  1. Verify that a processor is installed in the socket required to support the adapter.
    For more information, see the product user guide or QuickSpecs documents on the Hewlett Packard Enterprise website:
  2. If applicable, either add a processor or remove the adapter in X.
  3. Update the adapter firmware if it is not up-to-date.
    • If the server hardware is not in Unmanaged state, update the adapter firmware using HPE OneView.

    • Otherwise, boot into the Service Pack for ProLiant (firmware bundle) that is part of the HPE Synergy software release and update the firmware using Smart Update Manager (SUM).

  4. Remove and then reinstall the adapter.
  5. For iLO5-based servers, verify if iLO MCTP Discovery is disabled for the server or specific adapter mezzanine port:
    1. Click System Information in the navigation tree, and then click the Device Inventory tab.
    2. Click Discovery.
    3. If disabled, MCTP Factory Reset.
    4. Click Yes.
  6. Replace the adapter.