3120-HPE Persistent Memory Health Error

Symptom

3120-HPE Persistent Memory Health Warning - Processor X DIMM Y - The Persistent Memory Module reported an unsafe shutdown.

Cause

The HPE Persistent Memory module reported an unsafe shutdown. This error can be caused by an unexpected power loss before data could be saved to the persistent media on the module.

Action
  1. Review the Integrated Management Log for events related to the error, and follow any recommended actions.
  2. If the issue persists, confirm that the System ROM and System Programmable Logic Device version are current.
    For more information, see the following topic in the troubleshooting guide for your product on the Hewlett Packard Enterprise website:
  3. Verify that the power supply is working, and replace it if needed.
    For more information, see the server maintenance and service guide for your product on the Hewlett Packard Enterprise website: