377-NVDIMM Error – Processor X, DIMM Y

Symptom

377-NVDIMM Error – Processor X, DIMM Y. NVDIMM set for interleaving enabled but system configured for interleaving disabled. NVDIMM has been disabled.

Solution 1
Cause

The NVDIMM configuration does not match the server configuration.

Action
Enable NVDIMM-N Memory Interleaving, and then reboot the server.

If all the other NVDIMMs in the interleaved set are still installed, the data on the NVDIMM will be available after rebooting.

If any of the other NVDIMMs in the interleaved set are missing, a different error message might occur.

For more information, see the HPE 16GB NVDIMM User Guide on the Hewlett Packard Enterprise website (https://www.hpe.com/info/NVDIMM-docs).

Solution 2
Action
Sanitize the NVDIMM. The data on the NVDIMM will not be available after sanitization.

For more information, see the HPE 16GB NVDIMM User Guide on the Hewlett Packard Enterprise website (https://www.hpe.com/info/NVDIMM-docs).