SymptomThe server failed to access the storage volumes for the boot connection using port X.
This alert is new starting with HPE OneView 4.2.
ID: server-hardware.profile.boot.device.somemissing
Severity: Warning
Health Category: Profile
Resource URI: /rest/server-hardware/{UUID}
CauseThe connection is configured with boot target information of a standby storage controller.
Action-
If full boot redundancy is not required, you can clear this alert as the server was able to access a volume associated with the other boot connection.
-
Verify that any manually specified boot target information is correct in the connection configuration of the profile.
-
Resolve any relevant errors or warnings on the logical interconnect and interconnect resources.
-
Verify that the storage system is online and accessible.
-
Verify that the server has permission to access the volume on the storage system, and that zoning is correctly configured.
After addressing all issues, HPE OneView will clear this alert after doing the following: