The server failed to access the storage volumes for the boot connection

Symptom

The server failed to access the storage volumes for the boot connection using port X.

This alert is new starting with HPE OneView 4.2.

ID: server-hardware.profile.boot.device.somemissing

Severity: Warning

Health Category: Profile

Resource URI: /rest/server-hardware/{UUID}

Cause

The connection is configured with boot target information of a standby storage controller.

Action
  1. If full boot redundancy is not required, you can clear this alert as the server was able to access a volume associated with the other boot connection.
  2. Verify that any manually specified boot target information is correct in the connection configuration of the profile.
  3. Resolve any relevant errors or warnings on the logical interconnect and interconnect resources.
  4. Verify that the storage system is online and accessible.
  5. Verify that the server has permission to access the volume on the storage system, and that zoning is correctly configured.
    After addressing all issues, HPE OneView will clear this alert after doing the following:
    • Gen9 servers—Reapply the "Adapter configuration and boot settings" of the profile.

    • Gen10 and newer servers—Power on the server to complete Power On Self-Test (POST).