A drive failure is imminent for the drive in bay X

Symptom

A drive failure is imminent for the drive in bay X. The drive has exceeded a threshold value for one of its predictive indicators. The drive is part of logical JBOD Y and is being used by server profile Z.

This alert is new starting with HPE OneView 4.2.

ID: hpris.HpSmartStorageDiskDrive.PredictiveFail.attachedjbod

Severity: Warning

Health Category: drive-enclosure

Resource URI: /rest/drive-enclosures/

Action
  1. Replace the drive in drive bay X.
  2. Verify the drive status and volume integrity by using the Smart Storage Administrator:
    • If this drive is part of a non-fault-tolerant configuration, back up all data before replacing the drive, and then restore all data.
    • If this drive is part of a fault-tolerant configuration, do not replace this drive unless all other drives in the volume are online.