The drive enclosure with serial number X is missing

Symptom

The drive enclosure with serial number X is missing.

ID: dfrm.DriveEnclosureMissing (followed by the serial number of the missing drive enclosure)

Severity: Critical

Health Category: Logical interconnect

Resource URI: /rest/sas-logical-interconnects

Action
  1. Reinstall the drive enclosure.
  2. If the original drive enclosure has failed, replace the missing drive enclosure with a drive enclosure that has no drives into the same bay by doing the following:
    1. Prior to replacing the drive enclosure, power off all the server profiles using the drive enclosure.
    2. Replace the missing drive enclosure with a drive enclosure that has no drives.
    3. Perform the "Replace missing drive enclosure" action.
    4. Transfer each drive from the prior drive enclosure to the matching drive bay in the replacement drive enclosure.
    5. Power on all the server profiles that use the drive enclosure.