The drive enclosure with serial number X is missing
The drive enclosure with serial number X is missing.
ID: dfrm.DriveEnclosureMissing (followed by the serial number of the missing drive enclosure)
Severity: Critical
Health Category: Logical interconnect
Resource URI: /rest/sas-logical-interconnects
- Reinstall the drive enclosure.
-
If the original drive enclosure has failed, replace the missing drive enclosure with a drive enclosure that has no drives into the same bay by doing the following:
- Prior to replacing the drive enclosure, power off all the server profiles using the drive enclosure.
- Replace the missing drive enclosure with a drive enclosure that has no drives.
- Perform the "Replace missing drive enclosure" action.
- Transfer each drive from the prior drive enclosure to the matching drive bay in the replacement drive enclosure.
- Power on all the server profiles that use the drive enclosure.