Storage system temperature status changed to X for location Y connected to controller Z
Alert Type ID: trap.cpqSs6TempStatusChange
Description: Storage system temperature status changed to X for location Y connected to controller Z.
Severity: Critical
Health Category: Thermal
Resource URI: /rest/server-hardware/{UUID}
Source MIB: CPQSTSYS-MIB
The agent has detected a change in the temperature status of a storage system. The variable
cpqSsBoxTempStatus
indicates the current temperature status.
These are the values for
cpqSs6TempStatusChange
:
other(1)
Temperature monitoring is not supported by this system or it is not supported by the driver.
ok(2)
The temperature is within normal operating range.
degraded(3)
The temperature is outside of normal operating range.
failed(4)
The temperature could permanently damage the system. The storage system will automatically shut down if this condition is detected.
noTemp(5)
This unit does not support temperature monitoring.
- If the temperature status is degraded or failed, shut down the storage system.
- Verify that the environment is properly cooled and that no components are overheated.