1942-Slot X Smart Array - Configured physical drives are missing

Symptom

1942-Slot X Smart Array - Configured physical drives are missing: (followed by a list of drives)

Cause
  • A drive is not installed correctly or has failed.

  • A cable is not installed correctly or has failed.

  • External storage enclosures might be powered off.

Action
  1. Power down the server.
  2. Verify that the cables are connected.
    For more information, see the server user guide for your product on the Hewlett Packard Enterprise website:
  3. Verify that all drives are fully seated.
  4. While the system is off, cycle power to any external enclosures.
  5. Power up the server.
  6. If the error persists, replace the drives.
    For more information, see the server maintenance and service guide for your product on the Hewlett Packard Enterprise website: