Environmental specifications

Specification Value
Temperature range1  
Operating 10ºC to 35ºC (50ºF to 95ºF)

Maximum rate of change is 10º C/hr (50º F/hr)

Storage 30ºC to 60ºC (-22ºF to 140ºF)

Maximum rate of change is 20º C/hr (68º F/hr)

Relative humidity 2  
Operating, maximum wet bulb temperature of 28°C (82.4°F) 20% to 80%
Nonoperating, maximum wet bulb temperature of 38.7°C (101.7°F) 5% to 90%
Altitude 3
Operating

3,048 m (10,000 ft)

This value may be limited by the type and number of options installed.

Nonoperating 9,144 m (30, 000 ft)
1

All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to 3,048 m (10,000 ft) is applicable. No direct sunlight allowed.

2

Storage maximum humidity of 90% is based on a maximum temperature of 45°C (113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 kPa.

3

Maximum allowable altitude change rate is 457 m/min (1,500 ft/min).