Symptom1940-Slot X Smart Array - The following logical drives are failed: (followed by a list of logical drives).
Cause- A cable is not installed correctly.
- A drive is not installed correctly or has failed.
Action-
Verify that all cables are connected properly and securely.
For more information, see "Resolving loose connections" in the troubleshooting guide for your product on the
Hewlett Packard Enterprise website:
-
Verify that all drives are fully seated.
-
Determine which drive is defective using the storage administrator.
-
Replace the defective cables, drive, or both.
For more information, see the
server maintenance and service guide for your product on the
Hewlett Packard Enterprise website: