1945-Slot X Smart Array - The following logical drives are degraded

Symptom

1945-Slot X Smart Array - The following logical drives are degraded (followed by a list of drives).

Cause
RAID fault tolerance is degraded due to one of the following:
  • Failed drive

  • Missing drive

  • Incorrect drive capacity

  • Incorrect drive type

  • Missing SAS cable

  • Rebuilding

Action
  1. Replace the failed drives indicated in the 0x1911 IML error.
    For more information, see the server maintenance and service guide for your product on the Hewlett Packard Enterprise website:
  2. Replace the missing drives indicated in the 0x1942 IML error.
  3. Allow sufficient time for rebuild to complete.
  4. Check the storage software for further details.

    For more information, see the storage software documentation on the Hewlett Packard Enterprise website (https://www.hpe.com/info/smartstorage-docs).