Power input module and RPS backplane characteristics
- HPE 800 W/900 W Gold AC Power Input Module (744689-B21)
- This module is compatible with the AC RPS backplane (745813-B21).
- The module wattage rating changes depending on whether one or two power input modules are installed in the
server:
- One power input module installed (nonredundant): 900 W
- Two power input modules installed (redundant): 800 W
-
HPE 900 W AC/240 V DC Gold Power Input Module (775595-B21)
- This module is compatible with the AC/240 V DC RPS backplane (814835-B21).
- The 240 V DC function of this module only applies to server installations based in China.
For more information about the power supply features, specifications, and compatibility, see the Hewlett Packard Enterprise website.