Installing the FlexibleLOM adapter

CAUTION:

The maximum inlet ambient temperature for most components installed in the system is 35°C (95°F). Some components, however, are subject to thermal limitations depending on the chassis model and the fan configuration. There are some hardware configurations where it is necessary to limit the number of drives installed in the chassis. For more information, see Temperature requirements.

Prerequisites
  • Verify that the FlexibleLOM riser cage is installed in the server.

  • Before installing this option, make sure that you have a T-10 and a T-15 Torx screwdrivers available.

Procedure
  1. Power down the server.
  2. Disconnect all peripheral cables from the server.
  3. Remove the server from the chassis.
  4. Remove the bayonet board.
  5. Remove the FlexibleLOM riser cage.
  6. Lay the FlexibleLOM riser cage on its side with the riser slots facing up to access the FlexibleLOM slot.
  7. Remove the FlexibleLOM slot blank.

    Removing the FlexibleLOM slot blank
  8. Install the FlexibleLOM adapter. Make sure that the board is firmly seated in the slot.

    Installing the FlexibleLOM adapter
  9. Install the FlexibleLOM riser cage.
  10. Install the bayonet board.
  11. Install the server into the chassis.
  12. Connect the LAN segment cables to the adapter.
  13. Connect all peripheral cables to the server.
  14. Power up the server.

The installation is complete.