PCIe accelerators

Chassis Fan configuration Number of drives supported by the server Maximum inlet ambient temperature
Apollo r2200 Gen10 Chassis

(12 LFF backplane)

Redundant and nonredundant 5 to 6 drives1

30°C (86°F)

5 to 6 drives2

30°C (86°F)

0 to 4 drives3

35°C (95°F)

Apollo r2600 Gen10 Chassis

(24 SFF or 16 SFF + 8 NVMe backplane)

Redundant and nonredundant 0 to 10 drives

35°C (95°F)

Apollo r2800 Gen10 Chassis

(24 SFF backplane with SAS expander)

Redundant and nonredundant 0 to 24 drives

35°C (95°F)

Apollo r2800 Gen10 Chassis

(16 NVMe backplane)

Redundant and nonredundant 0 to 8 drives

35°C (95°F)

1

The drive capacity must be less than 10 TB.

2

The drive capacity must be greater than or equal to 10 TB.

3

If the component is installed in server 1, and the server is installed in the

Apollo r2200 Gen10 Chassis

, drive blanks must be installed in drive bays 1-2 and 1-10. Similarly, if the component is installed in server 3, and the server is installed in the

Apollo r2200 Gen10 Chassis

, drive blanks must be installed in drive bays 3-2 and 3-10. For more information, see

Installing drive blanks and thermal bezel blanks for components with thermal limitations

.