GPU accelerators
Description | Chassis | Fan configuration | Number of drives supported by the server | Maximum inlet ambient temperature |
---|---|---|---|---|
NVIDIA Quadro P4000 GPU | Apollo r2200 Gen10 Chassis (12 LFF backplane) |
Redundant and nonredundant | 5 to 6 drives1 | 30°C (86°F) |
5 to 6 drives2 | Not supported | |||
0 to 4 drives3 | 35°C (95°F) |
|||
Apollo r2600 Gen10 Chassis (24 SFF or 16 SFF + 8 NVMe backplane) |
Redundant and nonredundant | 0 to 10 drives | 35°C (95°F) |
|
Apollo r2800 Gen10 Chassis (24 SFF backplane with SAS expander) |
Redundant and nonredundant | 0 to 24 drives | 35°C (95°F) |
|
Apollo r2800 Gen10 Chassis (16 NVMe backplane) |
Redundant and nonredundant | 0 to 8 drives | 35°C (95°F) |
|
NVIDIA Tesla M10 Quad GPU | Apollo r2200 Gen10 Chassis (12 LFF backplane) |
Redundant and nonredundant | 5 to 6 drives1 | Not supported |
5 to 6 drives2 | Not supported | |||
0 to 4 drives3, 4 | 35°C (95°F) |
|||
Apollo r2600 Gen10 Chassis (24 SFF or 16 SFF + 8 NVMe backplane) |
Redundant and nonredundant | 0 to 10 drives | 35°C (95°F) |
|
Apollo r2800 Gen10 Chassis (24 SFF backplane with SAS expander) |
Redundant and nonredundant | 0 to 24 drives | 35°C (95°F) |
|
Apollo r2800 Gen10 Chassis (16 NVMe backplane) |
Redundant and nonredundant | 0 to 8 drives | 35°C (95°F) |
|
NVIDIA Tesla P4 GPU | Apollo r2200 Gen10 Chassis (12 LFF backplane) |
Redundant and nonredundant | 5 to 6 drives1 | Not supported |
5 to 6 drives2 | Not supported | |||
0 to 4 drives3, 5 | 30°C (86°F) |
|||
Apollo r2600 Gen10 Chassis (24 SFF or 16 SFF + 8 NVMe backplane) |
Redundant and nonredundant | 0 to 10 drives | 25°C (77°F) |
|
Apollo r2800 Gen10 Chassis (24 SFF backplane with SAS expander) |
Redundant and nonredundant | 0 to 24 drives | 25°C (77°F) |
|
Apollo r2800 Gen10 Chassis (16 NVMe backplane) |
Redundant and nonredundant | 0 to 8 drives | 25°C (77°F) |
|
NVIDIA Tesla P40 GPU | Apollo r2200 Gen10 Chassis (12 LFF backplane) |
Redundant and nonredundant | 5 to 6 drives1 | Not supported |
5 to 6 drives2 | Not supported | |||
0 to 4 drives3, 6 | 25°C (77°F) |
|||
Apollo r2600 Gen10 Chassis (24 SFF or 16 SFF + 8 NVMe backplane) |
Redundant and nonredundant | 0 to 10 drives | 22°C (71.6°F) |
|
Apollo r2800 Gen10 Chassis (24 SFF backplane with SAS expander) |
Redundant and nonredundant | 0 to 24 drives | 22°C (71.6°F) |
|
Apollo r2800 Gen10 Chassis (16 NVMe backplane) |
Nonredundant | 0 to 8 drives | 25°C (77°F) |
|
Redundant | 0 to 8 drives | 28°C (82°F) |
||
NVIDIA Tesla P100 GPU | Apollo r2200 Gen10 Chassis7 (12 LFF backplane) |
Redundant and nonredundant | 5 to 6 drives1 | Not supported |
5 to 6 drives2 | Not supported | |||
0 to 4 drives3 | Not supported | |||
0 to 3 drives8 | 22°C (71.6°F) |
|||
Apollo r2600 Gen10 Chassis7 (24 SFF or 16 SFF + 8 NVMe backplane) |
Redundant and nonredundant | 0 to 10 drives | Not supported | |
0 to 6 drives9 | With mix of SFF and NVMe drives: Not supported With SFF drives only: 22°C (71.6°F) |
|||
Apollo r2800 Gen10 Chassis (24 SFF backplane with SAS expander) |
Redundant and nonredundant | 0 to 24 drives | Not supported | |
Apollo r2800 Gen10 Chassis (16 NVMe backplane) |
Redundant and nonredundant | 0 to 8 drives | 22°C (71.6°F) |
|
NVIDIA Tesla V100 16 GB GPU | Apollo r2200 Gen10 Chassis7 (12 LFF backplane) |
Redundant and nonredundant | 5 to 6 drives1 | Not supported |
5 to 6 drives2 | Not supported | |||
0 to 4 drives3 | Not supported | |||
Nonredundant | 0 to 3 drives8 | 22°C (71.6°F) |
||
Redundant | Not supported | |||
Apollo r2600 Gen10 Chassis7 (24 SFF or 16 SFF + 8 NVMe backplane) |
Redundant and nonredundant | 0 to 10 drives | Not supported | |
0 to 6 drives9 | Not supported | |||
Apollo r2800 Gen10 Chassis (24 SFF backplane with SAS expander) |
Redundant and nonredundant | 0 to 24 drives | Not supported | |
Apollo r2800 Gen10 Chassis (16 NVMe backplane) |
Nonredundant | 0 to 8 drives | Not supported | |
Redundant | 22°C (71.6°F) |
|||
Nonredundant | 0 to 4 drives10 | 22°C (71.6°F) |
||
NVIDIA Tesla V100 32 GB GPU | Apollo r2200 Gen10 Chassis7 (12 LFF backplane) |
Redundant and nonredundant | 5 to 6 drives1 | Not supported |
5 to 6 drives2 | Not supported | |||
0 to 4 drives3 | Not supported | |||
Nonredundant | 0 to 3 drives8 | 22°C (71.6°F) |
||
Redundant | Not supported | |||
Apollo r2600 Gen10 Chassis7 (24 SFF or 16 SFF + 8 NVMe backplane) |
Redundant and nonredundant | 0 to 10 drives | Not supported | |
0 to 6 drives9 | Not supported | |||
Apollo r2800 Gen10 Chassis (24 SFF backplane with SAS expander) |
Redundant and nonredundant | 0 to 24 drives | Not supported | |
Apollo r2800 Gen10 Chassis7 (16 NVMe backplane) |
Redundant and nonredundant | 0 to 8 drives | Not supported | |
0 to 2 drives11 | 22°C (71.6°F) |
|||
NVIDIA Tesla V100S GPU | Apollo r2200 Gen10 Chassis7 (12 LFF backplane) |
Redundant and nonredundant | 5 to 6 drives1 | Not supported |
5 to 6 drives2 | Not supported | |||
0 to 4 drives3 | Not supported | |||
Nonredundant | 0 to 3 drives8 | Not supported | ||
Redundant | 22°C (71.6°F) |
|||
Apollo r2600 Gen10 Chassis7 (24 SFF or 16 SFF + 8 NVMe backplane) |
Nonredundant | 0 to 6 drives9 | Not supported | |
Redundant | 22°C (71.6°F) |
|||
Apollo r2800 Gen10 Chassis (24 SFF backplane with SAS expander) |
Redundant and nonredundant | 0 to 24 drives | Not supported | |
Apollo r2800 Gen10 Chassis7 (16 NVMe backplane) |
Nonredundant | 0 to 8 drives | Not supported | |
Redundant | 22°C (71.6°F) |
|||
NVIDIA Tesla T4 GPU with three-slot secondary riser or FLOM riser | Apollo r2200 Gen10 Chassis (12 LFF backplane) |
Redundant and nonredundant | 5 to 6 drives1 | Not supported |
5 to 6 drives2 | Not supported | |||
0 to 4 drives3, 6 | 22°C (71.6°F) |
|||
Apollo r2600 Gen10 Chassis (24 SFF or 16 SFF + 8 NVMe backplane) |
Redundant and nonredundant | 0 to 10 drives | 19°C (66.2°F) |
|
Apollo r2800 Gen10 Chassis (24 SFF backplane with SAS expander) |
Redundant and nonredundant | 0 to 24 drives | 19°C (66.2°F) |
|
Apollo r2800 Gen10 Chassis (16 NVMe backplane) |
Redundant and nonredundant | 0 to 8 drives | 22°C (71.6°F) |
|
NVIDIA Tesla T4 GPU with five-slot secondary riser | Apollo r2200 Gen10 Chassis7 (12 LFF backplane) |
Redundant and nonredundant | 5 to 6 drives1 | Not supported |
5 to 6 drives2 | Not supported | |||
0 to 4 drives3 | Not supported | |||
0 to 3 drives8 | 30°C (86°F) |
|||
Apollo r2600 Gen10 Chassis7 (24 SFF or 16 SFF + 8 NVMe backplane) |
Redundant and nonredundant | 0 to 10 drives | Not supported | |
Nonredundant | 0 to 6 drives9 | 28°C (82°F) |
||
Redundant | 30°C (86°F) |
|||
Apollo r2800 Gen10 Chassis (24 SFF backplane with SAS expander) |
Redundant and nonredundant | 0 to 24 drives | Not supported | |
Apollo r2800 Gen10 Chassis (16 NVMe backplane) |
Redundant and nonredundant | 0 to 8 drives | Not supported | |
0 to 4 drives10 | Not supported | |||
0 to 2 drives11 | Not supported | |||
NVIDIA Tesla RTX4000 GPU with three-slot secondary riser or FLOM riser | Apollo r2200 Gen10 Chassis (12 LFF backplane) |
Redundant and nonredundant | 5 to 6 drives1 | 30°C (86°F) |
5 to 6 drives2 | Not supported | |||
0 to 4 drives3 | 35°C (95°F) |
|||
Apollo r2600 Gen10 Chassis (24 SFF or 16 SFF + 8 NVMe backplane) |
Redundant and nonredundant | 0 to 10 drives | 35°C (95°F) |
|
Apollo r2800 Gen10 Chassis (24 SFF backplane with SAS expander) |
Redundant and nonredundant | 0 to 24 drives | 35°C (95°F) |
|
Apollo r2800 Gen10 Chassis (16 NVMe backplane) |
Redundant and nonredundant | 0 to 8 drives | 35°C (95°F) |
|
NVIDIA Tesla RTX4000 GPU with five-slot secondary riser | Apollo r2200 Gen10 Chassis7 (12 LFF backplane) |
Redundant and nonredundant | 5 to 6 drives1 | Not supported |
5 to 6 drives2 | Not supported | |||
0 to 4 drives3 | Not supported | |||
0 to 3 drives8 | 35°C (95°F) |
|||
Apollo r2600 Gen10 Chassis7 (24 SFF or 16 SFF + 8 NVMe backplane) |
Redundant and nonredundant | 0 to 10 drives | Not supported | |
0 to 6 drives9 | 35°C (95°F) |
|||
Apollo r2800 Gen10 Chassis (24 SFF backplane with SAS expander) |
Redundant and nonredundant | 0 to 24 drives | Not supported | |
Apollo r2800 Gen10 Chassis (16 NVMe backplane) |
Redundant and nonredundant | 0 to 8 drives | Not supported | |
0 to 4 drives10 | Not supported | |||
0 to 2 drives11 | Not supported | |||
NVIDIA Tesla RTX8000 GPU with three-slot secondary riser or FLOM riser | Apollo r2200 Gen10 Chassis7 (12 LFF backplane) |
Redundant and nonredundant | 5 to 6 drives1 | Not supported |
5 to 6 drives2 | Not supported | |||
0 to 4 drives3 | Not supported | |||
0 to 3 drives8 | 35°C (95°F) |
|||
Apollo r2600 Gen10 Chassis7 (24 SFF or 16 SFF + 8 NVMe backplane) |
Redundant and nonredundant | 0 to 10 drives | Not supported | |
0 to 6 drives9 | 35°C (95°F) |
|||
Apollo r2800 Gen10 Chassis (24 SFF backplane with SAS expander) |
Redundant and nonredundant | 0 to 24 drives | Not supported | |
Apollo r2800 Gen10 Chassis (16 NVMe backplane) |
Redundant and nonredundant | 0 to 8 drives | Not supported | |
0 to 4 drives10 | Not supported | |||
0 to 2 drives11 | 35°C (95°F) |
The drive capacity must be less than 10 TB.
The drive capacity must be greater than or equal to 10 TB.
If the component is installed in server 1, and the server is installed in the
Apollo r2200 Gen10 Chassis, drive blanks must be installed in drive bays 1-2 and 1-10. Similarly, if the component is installed in server 3, and the server is installed in the
Apollo r2200 Gen10 Chassis, drive blanks must be installed in drive bays 3-2 and 3-10. For more information, see
Installing drive blanks and thermal bezel blanks for components with thermal limitations.
If NVIDIA Tesla M10 Quad GPUs are installed in the server, and the server is installed in the
Apollo r2200 Gen10 Chassis, the maximum inlet ambient temperature can be increased by installing drive blanks in specific drive bays. For more information, see
Installing drive blanks and thermal bezel blanks for components with thermal limitations.
If NVIDIA Tesla P4 GPUs are installed in the server, and the server is installed in the Apollo r2200 Gen10 Chassis, the maximum inlet ambient temperature can be increased by installing drive blanks in specific drive bays. For more information, see Installing drive blanks and thermal bezel blanks for components with thermal limitations.
If NVIDIA Tesla P40 GPUs or NVIDIA Tesla T4 GPUs in three-slot secondary riser are installed in the server, and the server is installed in the Apollo r2200 Gen10 Chassis, the drive blanks must be installed in specific drive bays. For more information, see Installing drive blanks and thermal bezel blanks for components with thermal limitations.
To ensure proper thermal cooling with NVIDIA Tesla P100 GPUs or NVIDIA Tesla V100 GPUs installed in three-slot secondary riser and NVIDIA Tesla T4 GPU, NIVIDIA Tesla RTX4000 GPU in five-slot secondary riser, the server must be installed in the Apollo r2200 Gen10 Chassis, the Apollo r2600 Gen10 Chassis or the Apollo r2800 Gen10 Chassis. The thermal bezel blanks must also be installed in specific drive bays. For more information, see Installing drive blanks and thermal bezel blanks for components with thermal limitations.
If the component is installed in server 1 and the server is installed in the Apollo r2200 Gen10 Chassis, bezel blanks must be installed in drive bays 1-9, 1-10 and 1-11. If the component is installed in server 3 and the server is installed in the Apollo r2200 Gen10 Chassis, bezel blanks must be installed in drive bays 3-9, 3-10 and 3-11. For more information, see Installing drive blanks and thermal bezel blanks for components with thermal limitations.
If the component is installed in server 1 and the server is installed in the Apollo r2600 Gen10 Chassis, bezel blanks must be installed in drive bays 1-9 to 1-14. If the component is installed in server 3 and the server is installed in the Apollo r2600 Gen10 Chassis, bezel blanks must be installed in drive bays 3-9 to 3-14. For more information, see Installing drive blanks and thermal bezel blanks for components with thermal limitations.
If the component is installed in server 1 and the server is installed in the Apollo r2800 Gen10 Chassis, the removable blanks must be installed in drive bays 2-1 to 2-4. If the component is installed in server 3 and the server is installed in the Apollo r2800 Gen10 Chassis, the removable blanks must be installed in drive bays 4-1 to 4-4. For more information, see Installing drive blanks and thermal bezel blanks for components with thermal limitations.
If the component is installed in server 1 and the server is installed in the Apollo r2800 Gen10 Chassis, the bezel blanks must be installed in drive bays 1-3, 1-4, 2-1, 2-2, 2-3 and 2-4 . If the component is installed in server 3 and the server is installed in the Apollo r2800 Gen10 Chassis, the bezel blanks must be installed in drive bays 3-3, 3-4, 4-1, 4-2, 4-3 and 4-4. For more information, see Installing drive blanks and thermal bezel blanks for components with thermal limitations.