HPE Persistent Memory module

Enhanced processor performance does not support the HPE Persistent Memory module.

Chassis Fan configuration Number of drives supported by the server Maximum inlet ambient temperature
Apollo r2200 Gen10 Chassis

(12 LFF backplane)

Redundant and nonredundant 5 to 6 drives1 Not supported
5 to 6 drives2 Not supported
0 to 4 drives3 22°C (71.6°F)
Apollo r2600 Gen10 Chassis

(24 SFF or 16 SFF + 8 NVMe backplane)

Redundant and nonredundant 0 to 10 drives 22°C (71.6°F)
Apollo r2800 Gen10 Chassis

(24 SFF backplane with SAS expander)

Redundant and nonredundant 0 to 24 drives 22°C (71.6°F)
Apollo r2800 Gen10 Chassis

(16 NVMe backplane)

Redundant and nonredundant 0 to 8 drives 25°C (77°F)
1

The drive capacity must be less than 10 TB.

2

The drive capacity must be greater than or equal to 10 TB.

3

If the component is installed in server 1, and the server is installed in the Apollo r2200 Gen10 Chassis, drive blanks must be installed in drive bays 1-2 and 1-10. Similarly, if the component is installed in server 3, and the server is installed in the Apollo r2200 Gen10 Chassis, drive blanks must be installed in drive bays 3-2 and 3-10. For more information, see Installing drive blanks and thermal bezel blanks for components with thermal limitations.