Environmental specifications
Specification | Value |
---|---|
Temperature range1 | — |
Operating2 | 10°C to 35°C (50°F to 95°F) |
Nonoperating | -30°C to 60°C (-22°F to 140°F) |
Relative humidity (noncondensing) | — |
Operating | 10% to 90% 28°C (82.4°F) maximum web bulb temperature (noncondensing) across the operating temperature range of 0°C to 40°C. |
Nonoperating | 5% to 95% 38.7°C (101.7°F), maximum wet bulb temperature |
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 304.8 m (1.8°F per 1000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The upper limit and rate of change might be limited by the type and number of options installed.
2
System performance during standard operation might degrade if there is a fan fault or if the internal server temperature is above 30°C (86°F).