Re-entering the server serial number and product ID and selecting an advanced fan cooling method

After you replace the system board, the server serial number and the product ID must be configured:

Procedure
  1. Access System Utilities. During POST, press F9.
  2. On the System Utilities home screen, select System Configuration > BIOS/Platform Configuration (RBSU) > Advanced Options > Advanced Service Options.
  3. Select the Serial Number field and press Enter.

    The following alert appears:

    The serial number is modified by qualified service personnel and must match the serial number located on the chassis.

  4. Click OK.
  5. Type the serial number and press Enter.
  6. Select the Product ID field and press Enter.

    The following alert appears:

    Product ID is modified only by qualified personnel. This value must match the product ID located on the chassis.

  7. Type the product ID and press Enter.
  8. Press F10 to save the configuration.
  9. If the server is using Intel Xeon Gold 6244 processors, do the following:
    1. Select System Configuration > BIOS/Platform Configuration (RBSU) > Advanced Options > Fan and Thermal Options > Thermal Configuration.
    2. Select one of the following advanced fan cooling method:
      • Enhanced CPU Cooling

      • Maximum Cooling

  10. Save your setting.

The procedure is complete.