Media Module adapters
Description | Chassis | Fan configuration | Number of drives supported by the server | Maximum inlet ambient temperature |
---|---|---|---|---|
Media Module 10 GB 2P 568FLR-MMSFP+ | Apollo r2200 Gen10 Chassis (12 LFF backplane) |
Redundant and nonredundant | 5 to 6 drives1 | 30°C (86°F) |
5 to 6 drives2 | Not supported | |||
0 to 4 drives3 | 35°C (95°F) | |||
Apollo r2600 Gen10 Chassis (24 SFF or 16 SFF + 8 NVMe backplane) |
Redundant and nonredundant | 0 to 10 drives | 35°C (95°F) | |
Apollo r2800 Gen10 Chassis (24 SFF backplane with SAS expander) |
Redundant and nonredundant | 0 to 24 drives | 35°C (95°F) | |
Apollo r2800 Gen10 Chassis (16 NVMe backplane) |
Redundant and nonredundant | 0 to 8 drives | 35°C (95°F) | |
Media Module 10 GB 2P 568FLR-MMT | Apollo r2200 Gen10 Chassis (12 LFF backplane) |
Redundant and nonredundant | 5 to 6 drives1 | 30°C (86°F) |
5 to 6 drives2 | Not supported | |||
0 to 4 drives3 | 35°C (95°F) | |||
Apollo r2600 Gen10 Chassis (24 SFF or 16 SFF + 8 NVMe backplane) |
Redundant and nonredundant | 0 to 10 drives | 30°C (86°F) | |
Apollo r2800 Gen10 Chassis (24 SFF backplane with SAS expander) |
Redundant and nonredundant | 0 to 24 drives | 30°C (86°F) | |
Apollo r2800 Gen10 Chassis (16 NVMe backplane) |
Redundant and nonredundant | 0 to 8 drives | 30°C (86°F) |
1
The drive capacity must be less than 10 TB.
2
The drive capacity must be greater than or equal to 10 TB.
3
If the component is installed in server 1, and the server is installed in the
Apollo r2200 Gen10 Chassis, drive blanks must be installed in drive bays 1-2 and 1-10. Similarly, if the component is installed in server 3, and the server is installed in the
Apollo r2200 Gen10 Chassis, drive blanks must be installed in drive bays 3-2 and 3-10. For more information, see
Installing drive blanks and thermal bezel blanks for components with thermal limitations.