Installing the two-bay SFF drive cage option

Prerequisites

Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.

Procedure
  1. If installed, remove the front bezel.
  2. Power down the server.
  3. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  4. Disconnect all peripheral cables from the server.
  5. Remove the server from the rack.
  6. Remove the access panel.
  7. Remove the media bay blank:
    1. Remove the screws securing the media bay blank.

      Retain the screws for installing the optical drive cage.

    2. Disengage the media bay blank.
    3. Remove the media bay blank.

    Removing the media bay blank
  8. Install the drive cage.

    Installing the drive cage
  9. Install the drives.
  10. Connect the drive cables.
  11. Install the access panel.
  12. Install the server into the rack.
  13. Connect all peripheral cables to the server.
  14. Connect the power cords:
    1. Connect each power cord to the server.
    2. Connect each power cord to the power source.
  15. Power up the server.
  16. If removed, install the front bezel.