Installing the FlexibleLOM adapter

Prerequisites

Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.

Procedure
  1. If installed, remove the front bezel.
  2. Power down the server.
  3. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  4. Disconnect all peripheral cables from the server.
  5. Remove the server from the rack.
  6. Remove the access panel.
  7. Remove the FlexibleLOM riser cage.
  8. Remove the FlexibleLOM slot blank.

    Removing the FlexibleLOM slot blank
  9. Install the FlexibleLOM adapter.

    Installing the FlexibleLOM adapter
  10. Install the FlexibleLOM riser cage.
  11. Install the access panel.
  12. Install the server into the rack.
  13. Connect all peripheral cables to the server.
  14. Connect the power cords:
    1. Connect each power cord to the server.
    2. Connect each power cord to the power source.
  15. Power up the server.
  16. If removed, install the front bezel.

The installation is complete.