Systems Insight Display LEDs
The Systems Insight Display LEDs represent the system board layout. The display enables diagnosis with the access panel installed.
![](mag_011.png)
Description |
Status |
---|---|
Processor LEDs | Off = Normal Amber = Failed processor |
DIMM LEDs | Off = Normal Amber = Failed DIMM or configuration issue |
Fan LEDs | Off = Normal Amber = Failed fan or missing fan |
NIC LEDs | Off = No link to network Solid green = Network link Flashing green = Network link with activity If power is off, the front panel LED is not active. For status, see Rear panel LEDs. |
Power supply LEDs | Off = Normal Solid amber = Power subsystem degraded, power supply failure, or input power lost. |
PCI riser LED | Off = Normal Amber = Incorrectly installed PCI riser cage |
Over temp LED | Off = Normal Amber = High system temperature detected |
Proc DIMM Group LED | Off = Normal Amber = Failed DIMM or configuration issue |
Power cap LED | Off = System is in standby, or no cap is set. Solid green = Power cap applied |
When the health LED on the front panel illuminates either amber or red, the server is experiencing a health event. For more information on the combination of these LEDs, see Systems Insight Display combined LED descriptions.