Remove a power input module

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives, power input modules, and the internal system components to cool before touching them.
  1. If the server is using a single power input module only, remove all power from the server:
    1. Back up all server data.
    2. Power down the server.
    3. Disconnect all peripheral cables from the server.
  2. Release the power cords from the strain relief straps.
    • AC power input module
      Releasing the power cord from the strain relief strap
    • DC power input module
      Releasing the power cords from the strain relief strap
  3. For an AC power input module, do the following:
    1. Disconnect the power cord from the power input module.
      Disconnecting the power cord from AC power input module
    2. Remove the power input module.
      Removing a power input module
  4. For a DC power input module, do the following:
    1. Slide the power input module out of the bay just enough to access the ground cable screw.
    2. Detach the ground (earthed) cable from the power input module.
      Detaching the ground (earthed) cable from the power input module
    3. Remove the terminal block connector from the power input module.
      Removing the terminal block connector from the power input module
    4. Remove the power input module.
      Removing a power input module