LFF drive LED definitions

LFF drive LED definitions
Item Definition
1 Fault/UID (amber/blue)
2 Online/Activity (green)
Online/Activity LED (green) Fault/UID LED (amber/blue) Definition
On, off, or flashing Alternating amber and blue One or more of the following conditions exist:
  • The drive has failed.

  • A predictive failure alert has been received for this drive.

  • The drive has been selected by a management application.

On, off, or flashing Solid blue One or both of the following conditions exist:
  • The drive is operating normally.

  • The drive has been selected by a management application.

On Flashing amber A predictive failure alert has been received for this drive. Replace the drive as soon as possible.
On Off The drive is online but is not currently active.
1 flash per second Flashing amber Do not remove the drive. Removing the drive might terminate the current operation and cause data loss.

The drive is part of an array that is undergoing capacity expansion or stripe migration, but a predictive failure alert has been received for this drive. To minimize the risk of data loss, do not remove the drive until the expansion or migration is complete.

1 flash per second Off Do not remove the drive. Removing the drive might terminate the current operation and cause data loss.

The drive is rebuilding, erasing, or is part of an array that is undergoing capacity expansion or stripe migration.

4 flashes per second Flashing amber The drive is active but a predictive failure alert has been received for the drive. Replace the drive as soon as possible.
4 flashed per second Off The drive is active and is operating normally.
Off Solid amber A critical fault condition has been identified for this drive and the controller has placed it offline. Replace the drive as soon as possible.
Off Flashing amber A predictive failure alert has been received for this drive. Replace the drive as soon as possible.
Off Off The drive is offline, a spare, or not configured as part of an array.