Install the PCI riser cage

CAUTION: To prevent damage to electrical components, properly ground the server before beginning any installation procedure. Improper grounding can cause electrostatic discharge.
  1. Connect the power cable to the riser board.
    Connecting the power cable to the riser board
  2. Install the PCI riser cage:
    1. On the right side of the PCI riser cage, align the small tab on the drive cage with the notch on PCI riser cage.

      On the left side of the PCI riser cage, align the pin with the notch on the rear panel.

    2. Tighten the thumbscrew to secure the PCI riser cage to the rear panel.
    3. Tighten the captive screw to secure the PCI riser cage to the system board.
      Installing the PCI riser cage
  3. If cabled expansion boards are installed on the PCI riser cage, connect all necessary internal cabling to the expansion boards.

    For more information on these cabling requirements, see the documentation that ships with the option.

  4. Install the access panel.
  5. Install the server into the rack.
  6. Power up the server.