Removing and replacing the non-hot-plug power supply

Prerequisites

Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.

Procedure
  1. If installed, remove the bezel.
  2. Power down the server.
  3. Access the product rear panel.
  4. Release the power cord from the strain relief clip.



  5. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  6. Remove the server from the rack.
  7. Place the server on a flat, level work surface.
  8. Remove the access panel.
  9. Remove the left rail.
    1. Pull the latch on the inner rail.
    2. Detach the inner rail from the server.


  10. Remove the non-hot-plug power supply.
    1. Disconnect the power supply cable.
    2. Remove four screws.
    3. Remove the power supply.


To replace the component, reverse the removal procedure.