Installing an energy pack

Prerequisites
Before you perform this procedure:
Procedure
  1. If installed, remove the front bezel.
  2. Power down the server.
  3. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  4. Disconnect all peripheral cables from the server.
  5. Do one of the following:
  6. Remove the access panel.
  7. Remove the air baffle.
  8. Install the energy pack.

    Installing the energy pack
  9. Route the energy pack cable as shown in below illustration.

    Routing the energy pack cable
  10. Connect the storage controller backup power cable.
  11. Install the air baffle.
  12. If removed, install the secondary riser cage.
  13. Install the access panel.
  14. Install the server into the rack.
  15. Connect all peripheral cables to the server.
  16. Connect each power cord to the server.
  17. Connect each power cord to the power source.
  18. Power up the server.
  19. If removed, install the front bezel.

The installation is complete.